Two important indicators for evaluating the light distribution performance of LED road lighting fixtures - Talking about LED road lighting energy saving from the perspective of light distribution design

June 11, 2023

1 Introduction

In today's era of scarce resources, low-carbon economy, energy-saving emission reduction, green lighting and other related topics are not uncommon, and the state-advanced LED solid-state lighting technology has developed rapidly. LED chip maker Cree announced in March 2010 that its chip efficacy reached 208 lm / W (laboratory data), and its mature flagship product has exceeded 130 lm / W. It can be foreseen that the LED light source will soon reach and exceed the light efficiency of the traditional light source, and its energy-saving benefits gradually emerge. However, in the development process of road lighting fixtures, there are still many technical difficulties, such as power loss, heat dissipation technology, secondary optical design, etc., which makes the overall light efficiency of the lamps greatly reduced, and the efficiency of the lighting system is less than 75lm /W. So far, LED road lighting is still in the demonstration stage of government-led demonstration. The entire LED road lighting industry lacks practical application experience. There is a certain gap between lighting development and lighting applications, for example, secondary lighting design and application of lamps. The gap in demand causes the output luminous flux of the LED road luminaire to be projected onto the road surface, and there is a problem that the brightness is insufficient or the utilization factor is too low, which results in an energy saving effect of the LED road lighting. This paper will discuss how to improve the energy-saving effect of LED road lighting fixtures from the perspective of light distribution design. It is necessary to evaluate the light distribution performance of road lighting fixtures by using the coefficient CU and the illumination brightness ratio E / L in addition to the illumination brightness uniformity index. Good or bad, and summed up the problems in the design of road lighting.

2 Two important indicators for evaluating the performance of road lighting design

In the LED lighting industry, energy conservation is one of the main highlights of speculation, but from the experience of actual engineering cases, its energy-saving effect is far less impressive than the manufacturers claim, if without sacrificing lighting levels and effects, Not even as efficient as traditional high pressure sodium lamps. There are many reasons for this. For example, the problem of heat dissipation technology causes the phosphor to age after being heated, and its conversion light efficiency is reduced. When power supply is lost, many manufacturers do not consider the system light effect caused by power loss when evaluating the LED energy saving effect; The problem of secondary light distribution, the illuminating of many lamps is unreasonable, resulting in a lot of light flowing out of the road surface, and some of the light is irradiated to the area far away from the road, which not only wastes energy, but also causes adverse effects such as light pollution and light intrusion. There is a lack of technical indicators in the industry to evaluate the performance of light distribution, and optical engineers in the industry do not understand the application requirements of road lighting. When they are doing LED lighting design, the main goal is to meet the CJJ45-2006 urban road lighting design. The technical parameters specified in the standard for uniformity and glare are not enough for what kind of light distribution is more suitable for road lighting. The CJJ45—2006 standard is mainly a specification for road lighting design, and has limited constraints on the design of road lighting design. Moreover, the standard is mainly based on traditional light sources, and the binding force is very low for the LED road lighting.

What kind of light distribution is more suitable for road lighting? In short, it is to use less light to achieve the technical parameters specified in the road lighting specifications, and to improve the uniformity and reduce the glare value as much as possible. However, in the design of the light distribution, the lack of technical indicators to evaluate the quality of the light distribution, resulting in a mixed situation in the industry. A good light distribution design, first of all to meet the illumination uniformity, has reached a consensus in the industry, the general optical software can achieve illumination uniformity simulation. Since there is no optical software loading road surface brightness coefficient library, optical designers can not simulate the uniformity of road surface brightness of different materials, so most of the light distribution design in the industry can not meet the brightness uniformity UL or overall uniformity UO, even the industry There is still not enough knowledge of brightness uniformity. In addition to satisfying the illuminance and brightness uniformity, it is also necessary to consider whether the utilization factor is high, whether the ratio of illuminance to brightness is low enough, and whether there is an energy saving effect. After studying and comparing the light distribution curves of different manufacturers, the author proposes to use the utilization coefficient CU and the illumination brightness ratio E / L to evaluate the light distribution performance, which is enough to highlight its optical properties.

The pros and cons of energy.

2. 1 Coefficient of Utilization

The utilization factor refers to the percentage of the luminous flux received by the road calculation surface as a percentage of the total luminous flux output by the luminaire. It can be calculated by the formula (1). The relationship between the coefficient CU and the average illuminance E and the power density LPD is obtained by the formulas (2) and (3). It can be seen from equation (3) that the power density LPD is inversely proportional to the utilization factor CU, that is: the utilization factor CU can be used to directly reduce the power density LPD value to achieve the effect of energy saving. Only the light distribution design with high coefficient can ensure the road surface has Sufficient illumination and brightness. In the traditional road lighting industry, the denominator part of formula (1) has been defined as the luminous flux of the light source. Since the luminous flux of the LED light source is more complicated by the influence of the luminaire, the luminous flux of the traditional light source is difficult to define. This paper recommends using the luminous flux of the luminaire to define Use coefficients to facilitate calculations and promotion of this technical indicator.

CU--utilization coefficient;

u———the luminous flux that is irradiated to the calculation surface of the road, in units of lumens;

o———The total luminous flux output by road lamps, in units of lumens;

E———average illumination, unit: lux;

MF———Maintenance factor, the illuminance reduction factor caused by the decrease of luminous flux output of the luminaire during the use of the luminaire;

W———Road road width, unit: meter;

S———light pole spacing, unit: meter;

η ———System light efficiency of the luminaire, the output luminous flux of the complete set of LED luminaires divided by the power consumption, unit: lumens / watt;

LPD—Power density, the power consumption per unit of area.

In general, the lower the height of the pole and the wider the road, the higher the utilization factor. Figures 1 and 2 show the relationship between the utilization factor CU and the aspect ratio (W / H). If the lateral light distribution design of the luminaire is too wide (as shown in Figure 1), when applying to a narrower road (such as 2 to 3 lanes), the utilization factor is too low, causing serious energy waste; The lateral light distribution design is too narrow (as shown in Figure 2), and when applied to wider roads, there is a problem of reduced uniformity.

2. 2 illuminance brightness ratio (E / L)

The illuminance brightness ratio refers to the ratio of the average illuminance to the average brightness of the road calculation surface, which can be calculated by the formula (4):

Eavg—the average illuminance in the road calculation plane;

Lavg—The average brightness in the road calculation plane.

The technical indicators are related to the type of light distribution of the luminaire, the material of the road surface, the incident angle of the light to the road surface, the position of the observer and the direction of the line of sight. For road lighting, the position of the observer recommended by the International Lighting Society is calculated from the distance road. The position is 60 meters away and the height is 1.5 meters. JTJ 026. 1-1999 The recommended asphalt pavement E / L ratio in highway tunnel ventilation lighting design is based on 15 to 22, and the cement pavement E / L ratio is based on 10 to 13. According to the author's experience, the optimized design of the light distribution can make the ratio lower, even lower than the recommended range of the specification, that is: higher brightness can be achieved with less luminous flux [1]. If the design of the light distribution is unreasonable, it may cause the E / L ratio to be too large, even exceeding the recommended value range, resulting in the problem that the illumination is up to standard and the brightness is not enough. According to CJJ45-2006, the standard of brightness 2cd / m2 corresponds to 30lx illuminance, and the illuminance brightness ratio E / L is based on 15 values. According to the author's experience, when applied to the R3 asphalt pavement recommended by the standard, general road lamps are equipped with The illuminance ratio of light is in the range of 14 to 19 [1], that is, an illumination of 28 to 38 lx is required to achieve a brightness level of 2 cd / m 2 on the R3 asphalt pavement. That is to say, by reducing the luminance ratio, it is possible to achieve an energy saving effect of 10% to 25%.

3 Examples of evaluating light distribution performance using CU and E/L technical indicators

The author selects 10 models (as shown in Figures 3 to 4). The light distribution curves from different manufacturers, in order to facilitate comparative analysis, correct the output luminous flux, select the total luminous flux of 120W total lamp power output is 9000lm (according to the system luminous efficiency 75lm / W Calculation). In the calculation process, the pavement material is selected from the R3 asphalt pavement, and the maintenance factor is taken according to 0.7. The 10 light distribution curves are respectively applied in different typical lighting scenes, and the calculation results of various scenes are compared, and the various light distributions are summarized. The performance is good or bad, as shown in Tables 1 to 4. The application scenarios in Table 1 are: road width is 7 m 2 lanes, 30 m single-sided cloth light, lamp pole height 8 m (distance ratio is 3.75); the scene in Table 2 is: road width is 10 5 m 3 lanes, 30 m single-sided cloth, 8 m (light height ratio 3.75); The scene in Table 3 is: Road width 25 m bidirectional 6 lanes (including 1 m intermediate barrier) ), the bilateral symmetric spacing of 30 meters, the height of the pole is 8 meters (the height ratio is 3.75); the scene in Table 4 is: the road width is 25 meters bidirectional 6 lanes (including 1 meter intermediate isolation belt), double The side symmetrical spacing is 30 meters, and the height of the pole is 10 meters (the height ratio is 3.0).

 

4 Problems found in the comparison table of calculation results

4. 1 Light distribution design ignores brightness uniformity

From the data listed in Tables 1 to 4, especially in the case where the aspect ratio is not more than 3.5, most of the light distribution design can meet the illumination uniformity index, but there are nearly half of the light distribution curve. The brightness uniformity indicator cannot be met in all of the application scenarios in this paper. In general, it is possible to achieve a light distribution design with an appropriate illuminance uniformity by appropriately reducing the distance ratio to 0.4 or more, but the longitudinal uniformity is difficult to increase by narrowing the distance ratio unless the distance ratio is small. . The author suggests that in the light distribution design, the brightness uniformity should be considered first, because the light distribution curve designed according to the brightness uniformity can generally meet the illumination uniformity requirement [2].

4. 2 Low utilization factor of many light distribution curves

From the data in Table 1 to Table 2, many of the light distribution designs are too wide in the horizontal direction, and the slope of the CU curve is small, and the rising speed is too slow. When applied to narrow roads, the problem of low utilization factor appears, which not only causes waste of energy problems. There is also the problem of light pollution or light intrusion. Individual light distribution designs, such as the distribution curve of Sym 4 in the list, have very low utilization coefficients in all applications in this paper. Compared with other lamps with the same output luminous flux, the illumination brightness is 50% lower. Nearly 50% of the energy is wasted.

4. 3 Symmetrical light distribution can not meet the requirements of road lighting

From the comparison results of Table 1 to Table 4, it is found that symmetric light distribution (such as Sym 1 ~ 3) is not suitable for single-sided or double-sided cloth lamps, and has the problem of low longitudinal uniformity; in the process of use, it needs to have a large The elevation angle may cause problems with excessive glare (such as Sym 4) or problems with reduced utilization factor (such as Sym 4). Symmetrical light distribution is more suitable for placement in the middle of the road, such as an application scenario installed in the center of the tunnel.

4. 4 Individual light distribution curve has the problem that the illumination brightness ratio E / L is too large

From the results of Tables 1 to 4, it is found that the light distribution curve Asm 3 has a problem that the E / L is too large in all application scenarios, that is, to achieve the same brightness standard, higher illumination is required, and more luminous flux is required. Irradiation on the same area of ​​the road, causing energy waste.

4. 5 Rectangular light distribution principle can not meet the road lighting requirements

It can be seen from the results of Tables 1 to 4 that the light distribution curve Asm 1 has the best uniformity of illumination. The light distribution is a typical rectangular asymmetric light distribution design, and the light distribution is completely customized according to the requirements of the iso-illuminance design, but the brightness is uniform. Very poor sex. At present, many LED street lamp manufacturers in the industry mainly push this type of light distribution, and even suggest that the standard setting department will issue this type of light distribution as a specification, and the consequences will lead to the consequences of the retrogression of China's lighting industry.

4. 6 SR technical indicators can be considered separately

In Tables 1 to 4, many SR technical indicators do not meet the requirements of 0.5 in the specification. I recommend to design SR technical indicators separately in the design of the light distribution. In the application scenarios with SR requirements, the technology can be designed separately. The light distribution curve of the indicator makes it possible to save a lot of LED chips and save energy in an application environment without SR requirements (such as viaducts, closed highways, etc.).

4. 7 Improve the energy saving benefits brought by CU

According to CJJ45-2006 regulations on power density LPD (as shown in Table 5), the utilization factor of traditional street lamps is not high enough, resulting in high-efficiency high-pressure sodium lamp road lamps (up to 140lm / W, such as some imported brands) The HPS250W can output 33,000 lm), and a large portion of the output luminous flux cannot be reached by the road calculation surface. The calculated power density in the scenes listed in Table 1 is 0. 5714 W/m2. If the illuminance standard is 10lx, only 286W/m2 is required. The two-lane LPD specified in CJJ is less than 0. 55W/m2. Compared, improving the CU's light distribution design can save nearly 50% of the power. If the design of the light distribution is unreasonable, such as the Sym4 light distribution in Table 1, it needs 0. 5714W/m2 to reach 10lx, and its energy saving effect is not as good as the traditional light source.

As far as the current comprehensive level of LED manufacturers is concerned, the system light efficiency of LED street lamps quickly exceeds 75 lm /W. I suggest that the standard setting department increase the CU index and appropriately increase the LPD standard of CJJ45-2006 as the light distribution design rule for LED street lamps. It can be performed according to the LPD listed in Table 6. Compared with Table 5, the average energy saving is 20% to 30%. It is predicted that the LPD value of LED road lighting may be reduced by 20% over the recommended value of Table 6 within three years.

4. 8 good light distribution design should be able to meet most application scenarios

From the calculation results comparison table 1 to Table 4, it is better to apply the ideal light distribution in the narrow 2 to 3 lane scenes in scenes 3 to 4, but it is not suitable for the light distribution of wide roads. In a narrow road application scenario, the scene on one side of the luminaire is relatively more difficult. The light distribution according to the aspect ratio W / H = 1 can be adjusted by adjusting the height of the pole (7 ~ 13. 5m). Picking arm (0 ~ 1. 5m), elevation angle (0 ~ 15 degrees) and lighting mode (intermediate arrangement, symmetric arrangement, staggered arrangement), etc., can meet most application scenarios of 6 ~ 42m; according to the height ratio S / H = 3. 75 Designed light distribution, by adjusting the height of the pole (7 to 13.5 meters), it can meet most application scenarios with a spacing of 20 to 50 meters. However, when applied to pavements of different materials, it is necessary to meet the brightness uniformity index, and the light distribution curve needs to be separately designed [2]. According to the R3 and C1 roads recommended by the specification, up to four types of light distribution can meet most of the application scenarios of road lighting in China.

5 Conclusion

The semiconductor white light lighting industry is in the ascendant, and the LED street lamp industry is just emerging. The industry has a lack of understanding of the needs of road lighting applications. The industry standards and specifications are not perfect. The entire LED road lighting industry is in the stage of exploratory innovation, so it is inevitable that there will be many understandings or technologies. The problem. In the process of writing this article, the author has received support from many manufacturers to provide original light distribution data for this article, and I would like to take this opportunity to express my sincere gratitude to them.

Edit: Cedar

문의하기

Author:

Ms. Mandy

이메일:

mandy@wosenled.com

Phone/WhatsApp:

+8613425434349

인기 상품
You may also like
Related Categories

이 업체에게 이메일로 보내기

제목:
이메일:
메시지:

Your message must be betwwen 20-8000 characters

  • 질문 보내기
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

송신